    impeller diameter and pump flow, head, shaft power have anything to do

    Time:2011年04月13日 人氣: 來(lái)源:本站原創(chuàng)

    For the same pump, when the speed is constant, change the impeller diameter, the performance can be cut the following law of conversion.

    impeller diameter and pump flow, head, shaft power have anything to do  impeller diameter and pump flow, head, shaft power have anything to do  impeller diameter and pump flow, head, shaft power have anything to do

    Where: Q1, H1, Pa1 - that when the impeller flow diameter D1, head, shaft power;

    Q2, H2, Pa2 - that when the impeller flow diameter D2, head, shaft power.